Inquiry Language Message Login Search


1-10V Dimming  Actuator

KA/D 04.T1.1 

  • Switching
  • Relative/Absolute dimming
  • Status report
  • Scene Function
  • Staircase Lighting
  • Preset Function
 

LED Dimming Actuator,4-Fold,350/700mA

KA/D 04.L1.1 

  • Switching
  • Relative/Absolute dimming
  • Status report
  • Scene Function
  • Staircase Lighting
  • Preset Function
 

Dimming Actuator1-Fold

KA/D 0403.1

  • Switching 
  • Relative dimming
  • Status report & error report
  • Control of the intensity value of the lamp
  • BUS reset function
  • Staircase lighting
  • Up to 15 scenes preset
  • Preset & preset preserve function
 

Dimming Actuator1-Fold

KA/D 0203.1

  • Switching 
  • Relative dimming
  • Status report & error report
  • Control of the intensity value of the lamp
  • BUS reset function
  • Staircase lighting
  • Up to 15 scenes preset
  • Preset & preset preserve function
 

Dimming Actuator1-Fold
KA/D0103.1

  • Switching 
  • Relative dimming
  • Status report & error report
  • Control of the intensity value of the lamp
  • BUS reset function
  • Staircase lighting
  • Up to 15 scenes preset
  • Preset & preset preserve function
 

Switch Actuator, 8-Fold, 10A

ARES-08/10.1

  • Scene control/preset via 8bit/1 bit commands 
  • Logic operation AND,OR,XOR,gate function
  • Forced operation and safty function
  • Manaul switching operation
  • Time function,on/of delay
  • Status check and response
  • Inversion of the output
  • Threshold function setup
 

Switch Actuator 4-Fold

KA/R 1216.1

  • Manual switching operation
  • Time function,on/off delay, scene control/preset via 8 bit/1 bit commands 
  • Logic operation AND,OR,XOR, etc. function
  • Status check and response
  • Forced operation and safety function
  • Reaction to threshold function
  • Control of electro thermal valve drives
  • Selection of preferred state after bus voltage failure and bus recovery
  • Staircase lighting functions with warning and adaptable staircase lighting time
 

Switch Actuator 4-Fold

KA/R 0816.1

  • Manual switching operation
  • Time function,on/off delay, scene control/preset via 8 bit/1 bit commands 
  • Logic operation AND,OR,XOR, etc. function
  • Status check and response
  • Forced operation and safety function
  • Reaction to threshold function
  • Control of electro thermal valve drives
  • Selection of preferred state after bus voltage failure and bus recovery
  • Staircase lighting functions with warning and adaptable staircase lighting time
 

Switch Actuator 4-Fold

KA/R 0416.1

  • Manual switching operation
  • Time function,on/off delay, scene control/preset via 8 bit/1 bit commands 
  • Logic operation AND,OR,XOR, etc. function
  • Status check and response
  • Forced operation and safety function
  • Reaction to threshold function
  • Control of electro thermal valve drives
  • Selection of preferred state after bus voltage failure and bus recovery
  • Staircase lighting functions with warning and adaptable staircase lighting time

 


 Room controller


  AMRM-41/00.1 


· Dry contact input, to switch lighting, open/close curtain,         activate Do Not Disturb and room service as well as                 emergency signal transmission, etc

· Switch output
· Dimming output
· Shutter control output
· Fan speed control
· Valve control

 

LED Dimming Actuator 
ADLD-04/03.1

  • Switching the LED light        ·  Relative dimming
  • Absolute dimming               ·  Status report, error report 
  • Setting 15 scenes                ·  Staircase lighting function
  • Bus recovery (or reset) function 

  • Staircase lighting function

  • Preset value and modify preset value functions

  • Set output current for per channel manually

  • Switch/relative dimming via manual buttons

 

Fan coil Controller

AFVF-01/220.1 


· Heating and cooling

· Output modes of Standby, Comfort, Night and Protection   according to user’s demands
· Control fan speed in 3 gears (High, Medium, and Low)           manually or automatically
· Achieve continuous or PWM output control by valves by PI     controlling value
· Obtain temperature data collection from local or BUS, and   achieve the monitoring function to actual temperature and   frost temperature
· Detect shutter’s on-off status or binary input
· Achieve the controlling by external controller (e.g. Panel of   Temperature Controller)


 

 Shutter Actuator

 AWBS-04/00.1 


· Movement UP/DOWN

· Stop/Louvre adjustment
· Move to position 0…100%
· Adjustment louvre to position 0…100% (only Blind working   mode)
· scenes
· Automatic sun protection
· Monitoring of wind, rain and frost protect (cyclical)

· Block, status report

· Forced operation

· LED display

· Two operation mode, Venetian Blind and Shutter



 
技术支持:弈动科技